Adjustable
Nucleic Acid Sequencers, Single and Dual

Left: Adjustable Height Sequencer, 52cm (h) x 33cm (w),
Cat. # SG-500-33. Right: Dual Adjustable Height Sequencer, 52cm (h) x 33cm
(w), Cat. # DASG-500-33. |
SINGLE ADJUSTABLE HEIGHT
SEQUENCER
C.B.S. SCIENTIFIC's
Adjustable Nucleic Acid Sequencers are available in two widths, 20cm or
33cm, for either the Maxam-Gilbert (33cm) or the Sanger-Coulson (20cm)
technique. Sequencing gel path length for either width can be adjusted
from 22cm up to 1 meter. The upper buffer reservoir rides on three 1-inch
diameter delrin rods and is secured at the desired height by three
stainless steel thumbscrews. These rods are arranged in a triangular
configuration on a 1/2" thick acrylic base to add strength and
stability to the entire system. Unit can be easily disassembled into
components for compact storage.
Each Sequencer includes:
 | Interlocking safety covers with attached leads
 | Leak-proof silicone gasket on the upper
reservoir to which the glass plates are clamped
 | Platinum electrodes
 | Leveling base and bubble level
 | Bussed together power leads (CE approved)
 | 6 molded white spring clamps
 | Buffer drainage ports |
| | | | | |
Custom features available:
 | Custom widths (e.g. 25cm and 38cm)
 | Flip-lid safety covers with detached power
leads |
|
|
DUAL ADJUSTABLE HEIGHT
SEQUENCER
The C.B.S. SCIENTIFIC
Dual Adjustable Sequencer features the same versatility and adjustability
as our Adjustable Sequencer (see left) while allowing the researcher to
run twice as many samples using less buffer and the same amount of
valuable bench space. The Dual Adjustable Sequencer is available in 20cm
and 33cm widths and with height capabilities of 42cm, 52cm, or 62cm. The
upper reservoir is divided in half, allowing the researcher to run
identical or independent buffer conditions on either side. This feature is
also convenient for the researcher who occasionally wants to run just one
side of the unit. A rotating base allows the unit to swivel, providing
easy access to either side.
Each Dual Sequencer includes:
 | Interlocking safety covers with attached leads
 | Leak-proof silicone gasket on upper reservoir
to which glass plates are clamped
 | Platinum electrodes
 | Leveling base and bubble level
 | Rotating base
 | Bussed together power leads (CE approved)
 | 12 molded white spring clamps
 | Buffer drainage ports |
| | | | | | |
Custom features available:
 | Custom widths (e.g. 25cm and 38cm)
 | Flip-lid safety covers with detached power
leads |
|
|
|